Archives

HD525

HD525 Data Sheet

The Model HD525-1023-B048 shown below is typical and representative of the HD525 Models. For more information on specifying a holding fixture, see the 500 SERIES OPTIONS page and 500 SERIES CREATING A MODEL NUMBER pdf.

hd525


hd525_graph

The maximum distance between mounting interfaces is directly related to the main beam length. Specify the distance between mounting interfaces to be at or slightly larger than the length of the part-to-be-handled. The fixture can be adjusted to accommodate smaller length parts, however, the main beam(s) extending from each end frame may be inconvenient. For more information see the 500 SERIES OPTIONS page and 500 SERIES CREATING A MODEL NUMBER pdf.
A smaller than standard swing radius may be recommended for some applications. See the “Technical Section” under “Holding Fixture Safety” on page 3 of 7 concerning “Unexpected Accident Loads” and the chart on page 4 of 7 referring to “Maximum Recommended Swing Radius”

Product Features:

  • Safety Factor: 2
  • Rated Load Capacity:
    • Dynamic, 0″ eccentricity: 500 lbs. (227 Kg.)
    • Dynamic, 5″ eccentricity: 255 lbs. (116 Kg.)
  • Operating Temperature: +32 to +104 °F (0 to +40 °C). Contact factory for special applications with extended operating temperatures.
  • Choice of Trunnion Interface/Mount/Clamp Options:
    • Angle Interface
    • Mounting Plate Interface
    • Board Clamp
  • Choice of Main Beam Length
  • Main Beam Ball Lock Pins: Reliably prevents End Frames from slipping on Main Beams
  • Casters: 5″ diameter x 2″ wide wheel with polyurethane tread sealed swivel bearing and Tech-lock brake
  • Gearbox: 50:1 ratio with 6″ diameter crank
  • Materials: Steel construction
  • Finish: Flotron Blue powder coat with selected parts zinc plated.
  • Trunnion Brake Knob
  • A smaller than standard swing radius may be recommended for some applications. See the “Technical Section” under “Holding Fixture Safety” on page 3 of 7 concerning “Unexpected Accident Loads” and the chart on page 4 of 7 referring to “Maximum Recommended Swing Radius”
  • Optional Main Beam Lengths
  • Optional Trunnion Interface/Mount/Clamp
  • Optional Index Plate
  • Optional Casters
  • Optional finishes for clean room compatibility
  • Optional Ground Lug and Drag Chain for use in electrostatically protected area (EPA’s)
  • For more about 500 Series Options click here
All data presented is based on no modifications to the product.

As Flotron is constantly improving products and methods of manufacturing, we reserve the right to modify and/or change design or specifications without notice. Please contact Flotron for verification of critical dimensions and specifications.

For 500 Series – Creating a Model Number pdf click here

For clarification of terms or phrases, please see the Holding Fixtures Definitions page.

HD510-HYD

HD510-HYD Data Sheet

The Model HD510-HYD-1023-B048-C5SPX shown below is typical and representative of the HD510-HYD Models. For more information on specifying a holding fixture, see the 500 SERIES OPTIONS page and 500 SERIES CREATING A MODEL NUMBER pdf.

hd510hyd

hd510hyd_graph

The maximum distance between mounting interfaces is directly related to the main beam length. Specify the distance between mounting interfaces to be at or slightly larger than the length of the part-to-be-handled. The fixture can be adjusted to accommodate smaller length parts, however, the main beam(s) extending from each end frame may be inconvenient. For more information see the 500 SERIES OPTIONS page and 500 SERIES CREATING A MODEL NUMBER pdf.
A smaller than standard swing radius may be recommended for some applications. See the “Technical Section” under “Holding Fixture Safety” on page 3 of 7 concerning “Unexpected Accident Loads” and the chart on page 4 of 7 referring to “Maximum Recommended Swing Radius”

Product Features:

  • Safety Factor: 2
  • Rated Load Capacity:
    • Dynamic, 0″ eccentricity: 175 lbs. (79 Kg.)
    • Dynamic, 5″ eccentricity: 175 lbs. (79 Kg.)
    • Note: The hydraulic cylinders are single acting and a minimum load of 30 lbs is recommended to activate the return (compression) stroke and to give good synchronization of the risers.
  • Operating Temperature: +32 to +104 °F (0 to +40 °C). Contact factory for special applications with extended operating temperatures.
  • Choice of Trunnion Interface/Mount/Clamp Options:
    • Angle Interface
    • Mounting Plate Interface
    • Board Clamp
  • Choice of Main Beam Length
  • Main Beam Ball Lock Pins: Reliably prevents End Frames from slipping on Main Beams
  • Casters: 5″ diameter x 1 ¼” wide wheel with Performa tread and Tech-lock brake
  • Gearbox: 40:1 ratio with 4″ diameter crank
  • Materials: Steel construction
  • Finish: Flotron Blue powder coat with selected parts zinc plated.
  • Trunnion Brake Knob
  • A smaller than standard swing radius may be recommended for some applications. See the “Technical Section” under “Holding Fixture Safety” on page 3 of 7 concerning “Unexpected Accident Loads” and the chart on page 4 of 7 referring to “Maximum Recommended Swing Radius”
  • Optional Gearbox: 50:1 ratio with 6″ diameter crank
  • Optional Main Beam Lengths
  • Optional Trunnion Interface/Mount/Clamp
  • Optional Index Plate
  • Optional Casters
  • Optional finishes for clean room compatibility
  • Optional Ground Lug and Drag Chain for use in electrostatically protected areas (EPA’s)
  • For more about 500 Series Options click here
All data presented is based on no modifications to the product.

As Flotron is constantly improving products and methods of manufacturing, we reserve the right to modify and/or change design or specifications without notice. Please contact Flotron for verification of critical dimensions and specifications.

For 500 Series – Creating a Model Number pdf click here

For clarification of terms or phrases, please see the Holding Fixtures Definitions page.

HD510

HD510 Data Sheet

The Model HD510-1023-IND15-B048 shown below is typical and representative of the HD510 Models. For more information on specifying a holding fixture, see the 500 SERIES OPTIONS page and 500 SERIES CREATING A MODEL NUMBER pdf.

hd510

hd510_graph

The maximum distance between mounting interfaces is directly related to the main beam length. Specify the distance between mounting interfaces to be at or slightly larger than the length of the part-to-be-handled. The fixture can be adjusted to accommodate smaller length parts, however, the main beam(s) extending from each end frame may be inconvenient. For more information see the 500 SERIES OPTIONS page and 500 SERIES CREATING A MODEL NUMBER pdf.
A smaller than standard swing radius may be recommended for some applications. See the “Technical Section” under “Holding Fixture Safety” on page 3 of 7 concerning “Unexpected Accident Loads” and the chart on page 4 of 7 referring to “Maximum Recommended Swing Radius”

Product Features:

  • Safety Factor: 2
  • Rated Load Capacity:
    • Dynamic, 0″ eccentricity: 175 lbs. (79 Kg.)
    • Dynamic, 5″ eccentricity: 175 lbs. (79 Kg.)
  • Operating Temperature: +32 to +104 °F (0 to +40 °C). Contact factory for special applications with extended operating temperatures.
  • Choice of Trunnion Interface/Mount/Clamp Options:
    • Angle Interface
    • Mounting Plate Interface
    • Board Clamp
  • Choice of Main Beam Length
  • Main Beam Ball Lock Pins: Reliably prevents End Frames from slipping on Main Beams
  • Casters: 5″ diameter x 2″ wide wheel with polyurethane tread sealed swivel bearing and Tech-lock brake
  • Gearbox: 50:1 ratio with 6″ diameter crank
  • Materials: Steel construction
  • Finish: Flotron Blue powder coat with selected parts zinc plated.
  • Trunnion Brake Knob
  • A smaller than standard swing radius may be recommended for some applications. See the “Technical Section” under “Holding Fixture Safety” on page 3 of 7 concerning “Unexpected Accident Loads” and the chart on page 4 of 7 referring to “Maximum Recommended Swing Radius”
  • Optional Main Beam Lengths
  • Optional Trunnion Interface/Mount/Clamp
  • Optional Index Plate
  • Optional Casters
  • Optional finishes for clean room compatibility
  • Optional Ground Lug and Drag Chain for use in electrostatically protected area (EPA’s)
  • For more about 500 Series Options click here
All data presented is based on no modifications to the product.

As Flotron is constantly improving products and methods of manufacturing, we reserve the right to modify and/or change design or specifications without notice. Please contact Flotron for verification of critical dimensions and specifications.

For 500 Series – Creating a Model Number pdf click here

For clarification of terms or phrases, please see the Holding Fixtures Definitions page.